Huadian Technology ›› 2018, Vol. 40 ›› Issue (6): 23-25.

Previous Articles     Next Articles

Regular deviation analysis and treatment of tube explosions caused by oxide scale clogging at final superheater of boilers

  

  1. Fujian Huadian Electric Power Engineering Company Limited, Fuzhou 350003,China
  • Online:2018-06-25 Published:2018-08-21

Abstract:

After the operation of the #2 boiler in a power plant, tube explosion caused by oxide scale clogging at final superheater has occurred many times. The explosion part of tube is analyzed and found to have regular deviation. Through investigation, the main reason for the deviation is improper pouring of thermal insulation castable material. It will lead to a change in the smoke flow field and the formation of flue gas corridor caused by central ash. By modifying the structure of the thermal insulation castable, the problem of ash accumulation and flue gas corridor in the central part is solved, and the hidden danger of the explosion tube can be eliminated.

Key words: