Huadian Technology ›› 2019, Vol. 41 ›› Issue (2): 28-31.

Previous Articles     Next Articles

Cause analysis of secondary blade cracking at the end of lowpressure rotor in a power plant

  

  1. Rundian Energy Science and Technology Company Limited,Zhengzhou 450052, China
  • Online:2019-02-25 Published:2019-03-13

Abstract:

During a class A overhaul of No.2 unit in a power plant, there are 27cracks fromlow pressure lefthanded fifth grade blade to righthanded fifth grade(that is the last second stage)blade.Through the comprehensive appearance inspection and laboratory test, the reason for the cracks on the low pressure fifth blade of No.2 unit are found.It can provide reference for the analysis and processing of related problems.

Key words: