Huadian Technology ›› 2019, Vol. 41 ›› Issue (5): 46-49.

Previous Articles     Next Articles

Economic analysis of low temperature flue gas waste heat utilization in distributed energy system

  

  1. 1.China Huadian Engineering Company Limited, Beijing 100170, China;2.National Energy Distributed Energy Technology R&D Center, Beijing 100170, China
  • Online:2019-05-25 Published:2019-06-04

Abstract:

Taking LM2500+G4 gas turbine combined cycle distributed energy system as a research object, the heat of low temperature flue gas is absorbed by expanded heat exchange surface at the tail of the waste heat boiler. And the waterwater heat exchanger and the hot water storage tank are arranged for hot water storage. There are 9 configuration schemes for domestic hot water supplying system using flue gas waste heat, according to 3 waste heat utilization amounts and 3 kinds of transmission modes.Their economical characteristics are analyzed under certain hot water or tap water price level. The investment recovery period of 9 configuration schemes are all between 1~3 years, which are of good economy. With unchanged water transmission mode, the more waste heat is utilized, the better system economy will be. And with constant waste heat utilization, the shorter water storage time is, the better system economy will be.