Huadian Technology ›› 2009, Vol. 31 ›› Issue (9): 39-41.
• 研究与开发 • Previous Articles Next Articles
ZHANG Yujun, WANG Yuxing
Received:
Revised:
Published:
Abstract: The reasons of leakage at welding seam of reheater tubes supports of 660MW unit in Hanfeng Power Plant of China Huaneng Group were analyzed. A reformation scheme was proposed and adopted, which advocates change the fixed support structure into movable support structure. After reformation, the leakage was not occurred again.
Key words: reheater, leakage, additional stress, reheating crack
ZHANG Yujun;WANG Yuxing. The reason analysis of leakage at welding seam of reheater tube supports in 660MW unit[J]. Huadian Technology, 2009, 31(9): 39-41.