Design of antipurge device for improving the accuracy of boiler secondary air quantity measurement

  

  1. Hubei Xisaishan Power Generation Company Limited, Huangshi 435000, China
  • Published:2019-06-25

Abstract:

Through the sampling pipeline transformation of boiler secondary air quantity in a thermal power unit, an antipurge device with control loop is added, to realize the remote online antipurging function of the sampling pipeline. It solves sampling pipeline blockage during measuring, improves the measuring accuracy of boiler secondary air quantity of 680MW units, and ensures the economy of combustion.