双水内冷汽轮发电机转子漏水原因分析及预防措施

周波,周贤志   

  1. 湖南省火电建设公司,湖南株洲412000
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2010-09-25 发布日期:2010-09-25

Analysis on reasons of water leakage in rotor of dual internal cooling turbine generator and preventive measures

ZHOU Bo, ZHOU Xianzhi   

  1. Hunan Province Thermal Power Construction Company, Zhuzhou 412000, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2010-09-25 Published:2010-09-25

摘要: 介绍了双水内冷汽轮发电机转子冷却水系统,分析了双水内冷汽轮发电机转子冷却水漏水的原因,提出了安装及运行过程中预防漏水的措施。

关键词: 双水内冷, 发电机, 漏水, 预防, 措施

Abstract: The rotor cooling water system of the dual internal water cooling turbine generator was introduced. The reasons of leakage of rotor cooling water of dual internal water cooling turbine generator were analyzed. The measures for prevention of water leakage in erection and operation process were put forward.