摘要:

摘要:M701F燃气轮机引进我国后相继出现了2级轮盘超温报警的现象,通过分析,确认2级轮盘超温的原因为燃气轮机老化导致冷却空气压力不平衡。采取了对2级静叶冷却空气节流孔板扩孔的处理方法,2级轮盘温度明显下降,机组效率和燃气轮机出力也有所降低。

关键词: 关键词:M701F燃气轮机, 老化, 轮盘, 温度

Abstract:

Abstract:After the gas turbine M701F was imported into our country, the over temperature alarms of the secondary stage rotor disk were occurred successively. Based on analysis, it was determined that the reason of the over temperature of secondary stage rotor disk is aging of the gas turbine, which leads the cooling air pressure to be unbalance. The orifices on the secondary vane fixed blade cooling air throttle oriice plate had been enlarged. The temperature of secondary stage rotor disk was reduced sharply, but the unit efficiency and the output power of the gas turbine were decreased somewhat.

Key words: Keywords:high cooling tower, conentional cooling tower, operation and maintenance, initial investment, cost recovery, economy