华电技术 ›› 2017, Vol. 39 ›› Issue (8): 21-23.

• 研究与开发 • 上一篇    下一篇

AP1000核电机组二回路系统加药量计算

  

  1. 国核工程有限公司,上海〓200233
  • 出版日期:2017-08-25 发布日期:2017-09-12

Addition dosage calculation of secondloop system for AP1000 nuclear power unit

  1. State Nuclear Power Technology Corporation, Shanghai 200233, China
  • Online:2017-08-25 Published:2017-09-12

摘要:

以AP1000核电机组为例,在凝结水精处理系统(CPS)投运和未投运两种运行模式下进行二回路系统加药量的计算,得出机组运行时氨与联氨的理论添加量,为AP1000核电机组二回路加药系统的设计及配置提供依据和参考。

关键词:

Abstract:

Taking the AP1000 nuclear power unit as an example, this paper calculated the addition dosage of secondloop system in operation mode and shutdown mode of condensate polishing system (CPS), and obtained the theoretical add amounts of ammonia and hydrazine when the unit is running, which provided a reference for the dosing system design and configuration of secondloop of AP1000 nuclear power unit.

Key words: