华电技术 ›› 2008, Vol. 30 ›› Issue (11): 51-52.

• 一线动态 • 上一篇    下一篇

给水泵再循环阀改造

杨军,孙立本   

  1. 辽宁华电铁岭发电有限公司,辽宁铁岭 112000
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2008-11-25 发布日期:2008-11-25

Reformation of recirculating valve of feed pump

YANG Jun, SUN Liben   

  1. Liaoning Huadian Tieling Power Generation Corporation Limited, Tieling 112000, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2008-11-25 Published:2008-11-25

摘要: 辽宁华电铁岭发电有限公司的给水泵再循环阀出现了阀门密封不严和泄漏问题,分析其主要原因是阀座密封面发生了气蚀、侵蚀和冲刷。采取了3项措施,对阀门结构进行了改造,改造后的给水泵再循环阀投入运行后,其密封和调节性能良好,运行过程中从未出现泄漏问题,取得了良好的经济效益。

关键词: 给水泵再循环阀, 侵蚀, 气蚀, 冲刷, 分析, 结构改造, 解决方法

Abstract: There were problems of sealing untightness and leakage occurred in the feed pump recirculating valve of Liaoning Huadian Tieling Power Generation Corporation Limited. The reasons found by analysis were cavitation, encroachment and attack occurred at the sealing face of the valve seat. The valve structure was reformed by adopting three measures. The sealing and adjustment performance of the reformed recirculating valve are excellent, and leakage fault des not occur again in operation. So a good economical benefit was obtained.

Key words: recirculating valve of feed pump, encroachment, cavitation, attack, analysis, structure reformation, solving method