600MW 超临界机组汽轮机中压缸启动及故障分析处理

何辉,吴强   

  1. 湖南华电长沙发电有限公司,湖南长沙 410203
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2009-03-25

Analysis of startup through IP cylinder and its fault treatment for 600MW supercritical unit

HE Hui,WU Qiang   

  1. Hunan Huadian Changsha Power Generation Corporation Limited,Changsha 410203, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2009-03-25

摘要: 介绍了某电厂一期工程2台600MW超临界机组汽轮机中压缸启动的过程和特点,详细分析了启动过程中存在的故障并提出了具体的处理措施。最后指出,中压缸启动方式可使机组的启动更安全、经济。

关键词: 超临界机组, 汽轮机, 中压缸启动, 故障分析, 处理

Abstract:

The process and features of startup through intermediate pressure(IP)cylinder of two 600MW units in some power plant project phase I were presented.The faults occurred in the process of startup through IP cylinder were analyzed in detail, and the relevant treatment measures were proposed. At last, it was pointed out that the tartup through IP cylinder is a safer and more economic way for unit startup.

Key words: super-critical unit, steam turbine, start-up through intermediate pressure (IP) cylinder, fault analysis, treatment