综合智慧能源 ›› 2023, Vol. 45 ›› Issue (10): 25-34.doi: 10.3969/j.issn.2097-0706.2023.10.004

• 优化与运行控制 • 上一篇    下一篇

考虑负载响应特性的数据中心综合能源系统优化调度研究

余文昶1(), 陈永刚1, 曹俊波1, 左鹿原2, 张相寅3,*(), 杨秀3   

  1. 1.中国华电集团有限公司上海分公司,上海 200120
    2.上海奉贤燃机发电有限公司,上海 201403
    3.上海电力大学 电气工程学院,上海 200090
  • 收稿日期:2023-05-06 修回日期:2023-06-01 出版日期:2023-10-25
  • 通讯作者: *张相寅(1999),男,在读硕士研究生,从事数据中心优化调度、综合能源系统等方面的研究,zhangxy96688@163.com
  • 作者简介:余文昶(1972),男,工程师,从事电力企业管理、综合能源服务等方面的工作,ywc@chd.com.cn
  • 基金资助:
    国家自然科学基金项目(52177098)

Optimal scheduling of the data center integrated energy system considering load response characteristics

YU Wenchang1(), CHEN Yonggang1, CAO Junbo1, ZUO Luyuan2, ZHANG Xiangyin3,*(), YANG Xiu3   

  1. 1. Shanghai Company,China Huadian Corporation Limited, Shanghai 200120,China
    2. Shanghai Fengxian Gas Turbine Company Limited, Shanghai 201403,China
    3. School of Electrical Engineering,Shanghai Electric Power University,Shanghai 200090,China
  • Received:2023-05-06 Revised:2023-06-01 Published:2023-10-25
  • Supported by:
    National Natural Science Foundation of China(52177098)

摘要:

为实现碳达峰、碳中和目标下的“算力+电力”协同,数据中心作为一种增长迅速、耗电量大的新型负载进行节能降碳,充分挖掘其调节潜力具有重大意义。为充分发挥数据中心负载灵活性,提出一种考虑负载响应特性的数据中心综合能源系统优化调度的方法。首先,建立了数据中心综合能源系统优化调度框架,对数据中心的负载响应特性和能耗设备进行建模,对数据中心冷、热、电3种负荷展开研究;其次,确定目标函数和约束条件,以数据中心能源系统运行成本最低为目标建立优化模型;最后,以某数据中心为例进行仿真分析,通过对算例进行不同场景对比分析发现,最佳策略能够有效降低系统成本和能耗,实现工作负载的最佳分配。

关键词: 碳中和, 数据中心, 负载响应, 优化调度, 综合能源, 节能降碳

Abstract:

In the collaboration of "computing power + electric power" under the goal of carbon peaking and carbon neutrality,the data center,whose power consumption is substantive and growing rapidly,has great potential in carbon emission reduction and load regulation. To give full play to the flexibility of data center loads,an optimal scheduling strategy of the data center integrated energy system considering the load response characteristics is proposed. Firstly,an optimized scheduling framework for the data center integrated energy system is established. The load response characteristics and equipment energy consumption of the data center are modelled,to study the cold,heat and electric loads of the data center. Then,the objective function and constraint conditions are determined,and the optimization model is established to minimize the operation cost of the data center energy system. Finally,the simulation analysis is made on a data center. Comparing the performances of the data center energy system under different scenarios, the optimal strategy with the optimal allocation of workloads is figured out which can effectively reduce the system cost and energy consumption.

Key words: carbon neutral, data center, load response, optimized scheduling, integrated energy, energy saving and carbon reduction

中图分类号: