Huadian Technology ›› 2010, Vol. 32 ›› Issue (11): 52-54.
• 技术交流 • Previous Articles Next Articles
WANG Qingdong
Received:
Revised:
Published:
Abstract: In the Shandong Bainian Electric Power Development Corporation Limited, the temperature of the exhaust flue gas was higher, which was caused by the larger air leakage and the lower heat exchange efficiency of the airpreheater. In order to raise the heat efficiency of the boiler, the problems existed in airpreheater were analyzed, and the rectification measures were formulated. Based on investigation and argumentation, the airpreheater was replaced by the rotary airpreheater. After the reformation, the heat efficiency of the boiler increased by 3%, and the economic benefit was remarkable.
Key words: air preheater, existing problem, reformation measure, benefit analysis
WANG Qingdong. Problems existing in airpreheater of WGZ670/1402 type boiler and reformation measure[J]. Huadian Technology, 2010, 32(11): 52-54.