Huadian Technology ›› 2010, Vol. 32 ›› Issue (4): 58-60.
• 技术交流 • Previous Articles Next Articles
WANG Yong, LIU Jianfeng
Received:
Revised:
Online:
Published:
Abstract: Combining with structure characteristics of singlering oil sealing system, the reasons of oil leakage of 600MW generator in a power plant were analyzed. The relevant prevention measures from respects of equipment structure, system operation and overhaul were put forward, which can be used as reference for operation and maintenance of oil sealing system of same units.
Key words: generator, single-ring oil sealing system, prevention measures
WANG Yong;LIU Jianfeng. Reason analysis of oil leakage of 600MW generator and countermeasures[J]. Huadian Technology, 2010, 32(4): 58-60.