Huadian Technology ›› 2010, Vol. 32 ›› Issue (5): 44-46.
• 技术交流 • Previous Articles Next Articles
YUAN Xiongjun1, LIU Li1, HU Yizhang2, ZHAO Yali2
Received:
Revised:
Published:
Abstract: The technical performance and the economical efficiency of several common configuration schemes of the condensate pump configuration for cogeneration unit were compared. The optimized configuration scheme of the condensate pump for cogeneration unit was proposed.
Key words: cogeneration unit, condensate pump, variable frequency, minimum annual cost method
YUAN Xiongjun;LIU Li;HU Yizhang;ZHAO Yali. Discussion of the condensate pump configuration schemes for power and heat cogeneration unit[J]. Huadian Technology, 2010, 32(5): 44-46.
/ Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2010/V32/I5/44
Optimization of deep frequency conversion transformation for condensate pump in 1000MW secondary reheat unit