Huadian Technology ›› 2011, Vol. 33 ›› Issue (11): 49-51.

• 技术交流 • Previous Articles     Next Articles

Analysis on output water test of condensate treating mixed bed

CUI Shaobo   

  1. Huadian International Zouxian Power Plant, Zoucheng 273522, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2011-11-25 Published:2011-11-25

Abstract: Combining with the condensate quality of eight generator units of Huadian International Zouxian Power Plant, according to the test and analysis on the monitoring indices of the output water of condensate treating mixed bed, the operator can find the failure controlled parameters in output water quality indices monitoring of mixed bed more conveniently; so the failure operation of the mixed bed with an outoflimited parameter was avoided, and more excellent water quality and steam quality were ensured.