Huadian Technology ›› 2011, Vol. 33 ›› Issue (7): 48-51.

• 技术交流 • Previous Articles     Next Articles

Analysis on coking of 300MW corner tangentialfired boiler

CHEN Xingyu1,ZHU Guangming2,WANG Xin1,JIAO Qingfeng2,DUAN Xuenong2   

  1. 1.Hunan Huadian Shimen Power Generation Corporation Limited , Changde 415300, China; 2.Test and Research Institute, Hunan Electric Power Corporation, Changsha 410007, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2011-07-25 Published:2011-07-25

Abstract: The reasons of coking occurred in a power plant due to firing highsulfur coal produced in Guizhou province were analyzed. The improvement measures were introduced, which were adopted by the power plant to alleviate the coking. These measures involve the coal blending, the air distribution, the oxygen control, the equipment reformation and other aspects. The coking was controlled effectively due to these measures without basic improvement of the coal grade.

Key words: high-sulfur coal, coking, analysis, measure