Huadian Technology ›› 2013, Vol. 35 ›› Issue (1): 54-56.

• 技术交流 • Previous Articles     Next Articles

Analysis on reasons of higher total hydrocarbon in generator stator cooling oil

GUO Guangwu   

  1. Datang Luoyang Thermal Power Plant, Luoyang 471039, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2013-01-25 Published:2013-01-25

Abstract: The reasons of higher total hydrocarbon in TBM-160-2 generator stator cooling oil were analyzed. The finding method of the overheat points of stator, the treatment method and the control measures of total hydrocarbon in operation were introduced. The results in this paper provide operation and maintenance experiences for largecapacity generator with oil cooled stator, which will be imported or manufactured in china.

Key words: steam turbine generator, stator core, total hydrocarbon, treatment