Abstract: The improper adjustment of feed water flow for supercritical oncethrough boiler became the important reason to lead unit outage. The feed water flow adjustment methods for oncethrough boiler under the wet state, the dry state and the transforming process of wet state to dry state were introduced in detail, and the matters needing attention in each period were presented, which can be used as reference for related personnel.
Key words: supercritical, once-through boiler, feed water flow, adjustment, dry state, wet state, transforming of wet state to dry state
YANG Feiping. Feed water flow control strategy for supercritical oncethrough boiler[J]. Huadian Technology, 2013, 35(4): 33-36.