Huadian Technology ›› 2009, Vol. 31 ›› Issue (12): 8-11.

• 专题综述 • Previous Articles     Next Articles

Study on flow and resistance characteristics of denitration installation using selective catalytic reduction method

LüTongbo1, LI Lin2,WANG Shurong1, WANG Zhiqiang2   

  1. 1.China Huadian Engineering Corporation Limited, Beijing 100035, China; 2.Energy and Power Engineering School of Shandong University, Jinan 250061, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2009-12-25

Abstract: The flow in SCR method denitration installation of a 300MW unit was simulated numerically by using of CFD software Fluent, and the influence of the guiding devices, the ammonia injection grid and the flue gas deflection angle of reactor on the system resistance characteristics was analyzed. The research result shows that the guiding devices and rectifier devices can greatly improve the flow in the installation, and the guiding plates can optimize the flow and reduce the resistance. In the ammonia injection grid, the influence of the wear plate on reactor system resistance is smaller, and proper change of the flue gas deflection angle can reduce the resistance loss.

Key words: selective catalytic reduction (SCR) method, flow characteristics, resistance characteristics, guiding plate, numerical simulation