华电技术 ›› 2009, Vol. 31 ›› Issue (6): 12-14.

• 专题综述 • 上一篇    下一篇

水电站发电机断路器选型与改造

徐涛   

  1. 浙江省江山市碗窑水库管理局须江电站,浙江江山 324100
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2009-06-25 发布日期:2009-06-25

Selection and reformation of generator breaker in hydropower station

XU tao   

  1. Xujiang Hydropower Station of Zhejiang Jiangshan Wanyao Reservoir Administrative Bureau,Jiangshan 324100, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2009-06-25 Published:2009-06-25

摘要: 中小容量的发电机断路器在国内水电站中的应用尚属起步阶段,其设计选型和改造经验有限。介绍了发电机断路器的特点,提出了发电机断路器选型时需要考虑的因素。目前广泛使用的真空断路器存在一些缺点,在实际运行中需对其进行改造,介绍了发电机断路器的改造过程与调试方法,以供同行参考。

关键词: 发电机, 断路器, 运行, 改造

Abstract:

The application of small and medium capacity generator breaker in domestic hydropower stations is in the beginning period, and the experience of their design, selection and reformation is very little. The characteristics of generator beaker was introduced in brief, and the factors must be considered in breafer type selection were put forward. There are some defects in current vacuum breaker, so the breaker must be reformed in practical operation. The reformation process and debug method of the generator breaker were described for reference of the same trade or occupation.