凝结水泵的变频改造

汤石敏1,方元2   

  1. 1.长沙电力职业技术学院,湖南长沙410131;2.珠海深能洪湾电力有限公司,广东珠海519100
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2011-06-25 发布日期:2011-06-25

Variable frequency reformation of condensate pump

TANG Shimin1, FANG Yuan2   

  1. 1.Changsha Electric Power Technical College, Changsha 410131, China; 2.Shenzhen Energy Zhuhai Hongwan Power Corporation Limited, Zhuhai 519100, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2011-06-25 Published:2011-06-25

摘要: 针对某厂凝结水泵系统高耗能、低效率的状况,论述了凝结水泵进行变频改造的必要性,分析了凝结水泵改造前、后运行可靠性和经济性的改善程度。凝结水泵改造后,减少了电能消耗,降低了运行成本,节能效果明显。

关键词: 凝结水泵, 变频改造, 节能

Abstract: Aiming at the higher energy consumption and lower efficiency of the condensate pump system in a power plant, the necessity of variable frequency reformation for the condensate pump was expounded. The improvement of operation reliability and economical efficiency of the condensate pump after reformation comparing with that before reformation was analyzed. After reformation of condensate pump, the power consumption was decreased, the operation cost was reduced, and obvious energy conservation effect was obtained.