摘要:

摘要:分析了某电厂300MW机组启机阶段3种不同上水方式的优、缺点,介绍了电动给水泵带汽动给水泵上水的操作过程,总结了操作注意事项,优化后提高了机组启动的可靠性和经济性。

关键词: 关键词:机组启动, 电动给水泵, 汽动给水泵, 上水方式, 优化

Abstract:

Abstract:The advantages and disadvantages of three different water feed modes of the 300MW unit in a power plant in startup stage were analyzed. The operating process of water feed mode of turbinedriven feed pump assisted by electric feed pump was introduced, and the matters needing attention in operation were summarized. After the optimization, the reliability and economic efficiency of unit startup were improved.

Key words: Key words:unit startup, electric feed pump, turbinedriven feed pump, water feed mode, optimization