华电技术 ›› 2016, Vol. 38 ›› Issue (7): 20-24.

• 研究与开发 • 上一篇    下一篇

600MW汽轮机的优化启动

  

  1. 湖南华电长沙发电有限公司,长沙〓410203
  • 出版日期:2016-07-25 发布日期:2016-09-23

Optimal start up on 600MW steam turbine

  1. Hunan Huadian Changsha Power Generation Company Limited, Changsha 410203,China
  • Online:2016-07-25 Published:2016-09-23

摘要:

摘要:根据湖南华电长沙发电有限公司机组现状,在安全、合理的情况下,对汽轮机启动冲转时间分配及启动参数进行了合理调整,并在实施过程中全程跟踪,使汽轮机的中速暖机时间由4.0h缩短为2.5h,提高了暖机效果,节省了启机能耗,增加了上网电量,并根据实际暖机情况,进一步提出增加汽缸烘干装置的优化措施。

关键词:

Abstract:

Abstract:According to the status of Hunan Huadian Changsha Power Generation Company Limited,this paper adjusts allocation of turning time of turbine startup and startup parameters under a reasonable condition. In the process of implementation,mediumspeed warming has shortened from 4.0h to 2.5h,which improves warming efficiency and ongrid energy. Finally,this paper proposes a optimization measure which is to add cylinder drying device.

Key words: