Reformation and optimization for waste heat recovery of rollingcylinder slag cooler in 490t/h CFB heatsupply unit

GUO Zengliang1,YUAN Xiongjun2   

  1. 1.Xuanhua Thermal Power Generation Corporation Limited of Hebei Construction & Investment Corporation Limited, Xuanhua 072100, China; 2.North China Power Engineering Corporation Limited, Beijing 100120, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2010-12-25 Published:2010-12-25

Abstract: Three feasible reformation schemes for waste heat utilization of the cylindrical slag cooler in 490 t/h CFB boiler of a power plant were put forward, and their economic efficiencies were analyzed and compared by using the equivalent enthalpy drop method. It is pointed out that the better economic efficiency for waste utilization can be obtained by using the cooling water with temperature as high as possible and its quantity as less as possible. Aiming at the characteristics of the heatsupply unit, a ‘combined switchovertype’ scheme for slag cooler waste utilization was put forward, and the contradiction between the highefficiency and safety of CFB slag cooler waste heat utilization in heatsupply unit was solved effectively. 

Key words: circulating fluidized bed boiler, cylindrical slag cooler, equivalent enthalpy drop method, combined switchover-type, waste heat recovery