Huadian Technology ›› 2010, Vol. 32 ›› Issue (2): 40-41.

• 技术交流 • Previous Articles     Next Articles

Analysis of single auxiliary operation mode for high capacity unit operating in low load condition

ZHAO Junbin   

  1. Shanxi Zhangshan Power Generation Corporation Limited, Changzhi 046021, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2010-02-25 Published:2010-02-25

Abstract: The unit of Shanxi Zhangshan Power Generation Corporation Limited operated in low load condition in long term, and the efficiency of its auxiliary was lower and the house service consumption rate was higher. Aiming this situation, an energy conservation operation experiment was accomplished, in which single feed pump, single primary induced/forced draft fan, two boiler circulation pumps and two mills were put into operation. The effective energysaving measures were adopted, and obvious energysaving effect was obtained.

Key words: high capacity unit, single auxiliary, test, energy conservation