Huadian Technology ›› 2010, Vol. 32 ›› Issue (3): 23-24.
• 研究与开发 • Previous Articles Next Articles
JI Qiang, SHI Zongguo, SHI Libin
Received:
Revised:
Online:
Published:
Abstract: In the operation of turbogenerator set, the overheat phenomenon of stator bar was happened occasionally. According to the water flow test, it is decided that the main reasons of higher temperature of the generator stator bar are the corrosion of stator bar and water tube blockage by foreign body, which causes the water path to be narrow and the flow velocity of stator cooling water to be slowly. After the bar had been purged by water hammer, the water flow is not exceeding the average by ±10% and is accordance with evaluation requirement. Finally, the concrete measures for prevention of generator stator bar corrosion were given.
Key words: generator, stator, bar, temperature rise
JI Qiang;SHI Zongguo;SHI Libin. Reason of higher temperature of stator bar in 600MW generator[J]. Huadian Technology, 2010, 32(3): 23-24.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/
https://www.hdpower.net/EN/Y2010/V32/I3/23
Operation region partition for hydraulic turbine generator units based on stability test data
Optimization strategy of multiple output cables samephase parallel operation for gas turbine generators
Setting coordination of field loss protection with admittance and excitation device low excitation limit
Field test, analysis and recommendations for injection stator grounding protection