Huadian Technology ›› 2017, Vol. 39 ›› Issue (12): 1-3.

    Next Articles

Side coal bunker opposed firing boiler primary airpowder balance test study

  

  1. State Power Investment Corporation Henan Electric Power Company Limited Center for Technology Information, Zhengzhou 450001, China
  • Online:2017-12-25 Published:2018-01-10

Abstract:

It is common that coal powder distribution unbalance of each combustor outlet of side coal bunker boiler. Combustors that closer to extension end have higher coal powder flow rate and higher air velocity. Combustors that closer to fixed end have lower coal powder flow rate and lower air velocity. This is the main cause of uneven combustion and primary air tube blockage. A new type of air velocity adjustment device was introduced. After installed between each distributor and combustor, airpowder velocity of each branch tube was effectively online balanced. The problem of boiler uneven combustion was solved.

Key words: