Huadian Technology ›› 2019, Vol. 41 ›› Issue (6): 6-12.

Previous Articles     Next Articles

Study on uniform flow technology of compact circular primary air duct at mediumspeed mill inlet

  

  1. 1.Guangdong Yuedian Jinghai Power Generation Company Limited, Jieyang 515223, China; 2.Xi’an Thermal Power Research Institute Company Limited,Suzhou Branch, Suzhou 215153, China;3.Electric Power Research Institute of Guangdong Power Grid Corporation, Guangzhou 510080, China
  • Published:2019-06-25

Abstract:

To solve the inaccurate online measurement of primary air flow rate at a medium speed mill inlet in a 1000MW coal fired power plant, flow field test, uniform flow optimization and practical transformation are conducted.The research can be applied for uniform flow The technology of compact large-scale circular duct.The technology can improve the uniformity of velocity distribution at the  measurement cross section and eliminate local vortex regions and back flow regions by flow split, diversion, rectification and uniform.The accurate measurement on the primary air flow rate is achieved and the its coefficient deviation can be kept below 3%. The automatic control valve is put into practice and works well and steady.The total current of the primary air fan decreases by 50A, the coal consumption rate reduces by 0.14g/(kW·h), and the annual fuel cost declines by 498000 Yuan.

Key words: