华电技术 ›› 2011, Vol. 33 ›› Issue (4): 9-11.

• 专题综述 • 上一篇    下一篇

1 000 MW汽轮发电机定子绕组温度监测与故障处理

李存怀1,杨磊2   

  1. 1.华电国际邹县发电厂,山东邹城 273522; 2.兖矿集团华聚能源股份有限公司,山东邹城 273500
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2011-04-25

Temperature monitoring and faults treatment for stator winding of 1 000 MW turbo generator

LI Cunhuai1, YANG Lei2   

  1. 1.Huadian International Zouxian Power Plant, Zoucheng 273552, China; 2.Huaju Energy Company Limited of Yanzhou Coal Mining Company, Zoucheng 273500, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2011-04-25

摘要: 华电国际邹县发电厂超超临界机组使用的1 000 MW汽轮发电机定子绕组个别测点温度显示值不正常,检查元件安装、接线情况并对存在问题的元件进行了跟踪测量,确定温度测量过程中存在电磁干扰和“接地环路”问题。针对发现的问题,对进行汽轮发电机定子绕组温度测量进行了优化改进,确保汽轮发电机定子温度测量的准确性。

关键词: 汽轮发电机, 定子绕组, 温度, 检测, 处理

Abstract: In the Huadian International Zouxian Power Plant, the displayed temperature data of several measuring points in stator winding of 1 000 MW turbogenerator were abnormal. The elements installation and connection were inspected; the problematical elements were tracked and measured. Based on this, it was determined that there was electromagnetic interference and‘ground loop’ problem in temperature measure process. Aiming at the found problems, the temperature measurement of the turbogenerator stator winding was optimized and improved, so the accuracy of the temperature measurement of turbogenerator stator winding was ensured.