Huadian Technology ›› 2021, Vol. 43 ›› Issue (11): 74-84.doi: 10.3969/j.issn.1674-1951.2021.11.009
• Key Technologies with Potential • Previous Articles Next Articles
DAI Baomin1(), LIU Shengchun1,*(), CAO Yu1, YANG Haining1, FENG Yining1, XIAO Peng2
Received:
2021-08-23
Revised:
2021-10-11
Online:
2021-11-25
Published:
2021-11-16
Contact:
LIU Shengchun
E-mail:dbm@tjcu.edu.cn;liushch@tjcu.edu.cn
CLC Number:
DAI Baomin, LIU Shengchun, CAO Yu, YANG Haining, FENG Yining, XIAO Peng. Efficiency enhancement technology and carbon emission prediction of refrigeration system taking CO2 natural refrigerant in supermarkets[J]. Huadian Technology, 2021, 43(11): 74-84.
Add to citation manager EndNote|Ris|BibTeX
URL: https://www.hdpower.net/EN/10.3969/j.issn.1674-1951.2021.11.009
Tab.1
Pros and cons of three types of CO2 refrigeration systems
系统形式 | 优势 | 劣势 |
---|---|---|
跨临界CO2增压制冷系统 | 制冷剂仅纯自然工质CO2;换热效率高,蒸发器小;技术不断革新、创新性高;在气候凉爽及严寒气候区域应用时,其系统能效高 | 系统压力高,零部件成本高;低温应用需要双级系统;在温暖及炎热气候区域应用时,其系统能效较低 |
CO2复叠制冷系统 | 高温级和低温级制冷系统的形式较简单;低温级制冷系统压力不高,部分部件可与HFC系统通用,成本较低;高温级制冷系统可采用HFC、HFO、碳氢化合物(HC)等制冷剂,在温暖及炎热气候区域,系统能效高 | 高、低温级制冷系统需采用2种制冷剂;冷凝蒸发器存在换热温差,低温级制冷系统的能效稍低;高、低温级制冷系统相互关联,如有故障会影响系统整体运行 |
CO2载冷剂制冷系统 | 高效利用CO2潜热;主回路可以是简单的制冷机组系统;可采用HFC,HFO,HC,氨(NH3)等制冷剂;系统运行压力基本无波动 | 额外的换热器及换热温差导致性能略微下降;需要专门的CO2液体泵,安装费较高;制冷技术人员对CO2液体泵的知识了解较少 |
Tab.2
Comparison of the efficiency enhancement solution,cost,complexity and application of transcritical CO2 booster refrigeration systems[13,14,15]
增效技术 | 方案 | 成本 | 复杂度 | 应用情况 |
---|---|---|---|---|
回热 | 在低压级压缩机和气体冷却器/冷凝器之间加入回热器,高压CO2流体从气体冷却器排出后进入回热器,与进入高压级压缩机前的CO2流体进行热交换,实现对气冷器出口CO2冷却,并能保证高压级压缩机入口的制冷剂全部蒸发 | 中等 | 中等 | 较多 |
平行压缩 | 在常规CO2增压系统中引入辅助压缩机,可实现将气液分离器中的饱和蒸汽直接压缩至排气压力,后被高压级压缩机吸入压缩,减小不可逆损失 | 中等 | 复杂 | 较多 |
机械过冷 | 机械过冷技术通过在气体冷却器/冷凝器出口和节流阀之间引入蒸气压缩制冷系统实现,该系统为辅助过冷系统或机械过冷系统。通过辅助过冷系统的蒸发过程可实现CO2流体的进一步冷却,CO2过冷度可通过调节辅助过冷系统的蒸发温度进行调节。辅助过冷系统的制冷剂可选HFCs,HCs等低GWP制冷剂 | 中等 | 中等 | 试验阶段 |
热电过冷 | 在气体冷却器/冷凝器出口和节流阀前加装由若干对热电偶组成的热电过冷器,实现对CO2流体的冷却,称为热电过冷。根据帕尔贴效应,热电过冷器的冷端与气体冷却器出口的CO2发生热量交换,降低了气体冷却器的出口温度,提高系统效率 | 较高 | 中等 | 较多 |
吸收式过冷 | CO2过冷也可通过吸收式制冷技术实现,以太阳能驱动的吸收式过冷CO2增压系统为例,太阳能集热器将入射的太阳辐射转化为热能,为发生器提供高温热源 | 高 | 复杂 | 理论阶段 |
超倍供液 | 超倍供液技术分为基于引射器和基于工质泵2种解决方案。中温级蒸发器出口的气液两相CO2流体与低温级压缩机排气混合首先进入次高压级气液分离器。对于液体引射器方案,气体冷却器出口的高压CO2流体作为液体引射器的一次流,中压气液分离器中的饱和CO2液体为二次流被一次流引射,混合后的流体进入次高压级气液分离器;采用工质泵的超倍供液方案,通过工质泵将中压级气液分离器中的液态CO2泵送至次高压级气液分离器 | 中等 | 中等 | 较多 |
多联引射 | 多联引射器包括2组CO2引射器,分别为液体引射器和气体引射器。液体引射器原理与超倍供液一致,气体引射器可将中压级气液分离器中的饱和气态CO2升压,实现高压CO2降压过程中的膨胀功回收,并且避免了这部分气体再经过高压级压缩机压缩。引射器的最优运行工况范围较窄,偏离最优工况后其性能显著恶化,实际引射器技术需引入多个不同最优工况范围引射器,使得系统在较宽运行范围内均取得较高能效 | 中等 | 复杂 | 较多 |
系统集成 | 可将生活热水、供暖、空调功能与CO2增压制冷系统相集成。将气体冷却器余热回收用于满足商超建筑的生活热水和供暖需求,温度较高段用于生产生活热水,温度较低段用于供暖,最低温度段能量品位较低,通过气体冷却器/冷凝器排至环境。在气液分离器前和节流阀后加装空调蒸发器,通过CO2流体蒸发为商超建筑提供空调供冷 | 较高 | 复杂 | 较多 |
Tab.3
Application situation of supermarkets taking CO2 refrigeration systems in the world[8,14-19]
分布 | 国家城市 | 企业 | 系统形式 | 项目详情 |
---|---|---|---|---|
欧洲 | 意大利,米兰 | — | 跨临界CO2增压制冷系统 | 地下水代替空气作为冷却流体来冷却跨临界状态的CO2:在夏季,使系统仍能处于亚临界运行状态,且可极大地降低能耗;在冬季,系统设计为跨临界模式运行,以满足超市对热水的需求 |
瑞士,里亚齐诺 | 米格罗提契诺 | 跨临界CO2增压制冷系统 | 安装第1个完全集成的CO2系统,可满足商店的制冷、冬季供暖和夏季空调需求。跨临界CO2压缩机系统具有过冷、热泵和冷水机组部分,并与2个独立的水箱一起工作,为空调提供冷冻水 | |
保加利亚,鲁塞 | 麦德龙 | 配有喷射器的跨临界CO2增压制冷系统 | 通过在冰箱上增加玻璃门,减少开口,达到节约能源的目的,同时新系统将实现至少20%的制冷省电和35%以上的供暖省电。系统的更换升级,极大地提高了其整体效率 | |
法国,多尔多涅 | Biocoop | CO2制冷系统 | 大金在法国市场的第1个CO2制冷系统于2018年12月5日在多尔多涅的食品分销商Biocoop肉类加工实验室安装完成 | |
英国,斯旺西 | 乐购超市 | CO2制冷系统 | 2006年安装了第1台跨临界CO2制冷系统后,装机量稳步增长 | |
丹麦,哥本哈根 | 航运公司DFDS | CO2冷藏集装箱 | 一家航运公司DFDS物流已开始使用50个由承运人制造的CO2冷藏集装箱来提供航运服务 | |
挪威,特隆赫姆 | EMA1000超市 | 带热回收的跨临界CO2增压制冷系统 | 应用带热回收的跨临界CO2增压制冷系统,可实现30%的节能效果 | |
瑞典 | Nordby超市 | 跨临界CO2增压制冷系统 | 应用跨临界CO2增压制冷系统实现了20%~30%的节能,同时提供了冷藏冷冻所需的制冷量和冬季供暖所需热量 | |
波兰 | 家乐福 | — | 46家门店将现有的制冷系统改造为CO2制冷系统 | |
芬兰 | Kesco零售商 | CO2制冷系统 | 使用CO2作为制冷剂的商店比使用其他制冷剂的商店节能30% | |
西班牙,加那利群岛 | SCM Frigo | 用于冷藏的跨临界CO2增压制冷装置 | 系统设计包括-2 ℃蒸发温度和38 ℃气体冷却器输出温度。2019年2月首次安装 | |
西班牙,阿利坎特 | EPTA公司 | 跨临界CO2增压制冷装置 | 一家商店安装了1个具有完全跨临界效率的跨临界CO2增压制冷装置 | |
克罗地亚 | 麦德龙 | 跨临界CO2增压制冷系统,亚临界CO2增压制冷系统 | 到2030年,在所有麦德龙商超中逐步淘汰氟利昂制冷剂,并用Natrefs替代。在保加利亚的11家商超中,2家有跨临界CO2增压制冷系统,3家有亚临界CO2增压制冷系统 | |
比利时,布鲁塞尔 | 德尔海兹 | CO2制冷装置 | 与当地承包商SABCOBEL合作,在德尔海兹商店安装了2个CO2制冷装置。超市于2018年6月开业,占地面积250 m2 | |
亚洲 | 中国,北京 | 麦德龙北京立水桥商场 | 跨临界CO2增压制冷系统 | 作为中国首家使用跨临界CO2增压制冷系统的商场,于2018年1月17日开业。相比R22制冷剂使用,跨临界CO2增压制冷系统可有效减少臭氧层的破坏,估算每天平均能耗下降约190 kW |
中国,北京 | 超市发 | 跨临界CO2增压制冷系统 | 整个店面的66台冷柜和4个冷藏库组成的制冷系统全部采用跨临界CO2平行压缩冷热一体化集成技术,制冷效率提高10倍,减少能耗约20% | |
中国,合肥 | 红府超市 | R134a/CO2 复叠制冷系统 | 通过引用CO2绿色冷媒技术,门店制冷设备不仅可实现15%左右的能效提升,同时可消除原系统制冷剂对大气臭氧层的破坏作用 | |
中国,武汉 | 华联超市 | R134a/CO2 复叠制冷系统 | — | |
泰国 | Tesco Lotus | CO2复叠制冷系统 | 亚洲第1家安装CO2复叠制冷系统的超市,由澳大利亚Frigrite公司建造,由Carrier公司安装 | |
日本,福冈 | 吉雄冰 | 跨临界CO2增压制冷系统 | 3个跨临界CO2增压制冷系统分别服务于1个4 700 m3(-25 ℃)的冷冻储藏室、1个3 700m3(5 ℃)的冷藏室和1个4 700 m3(5 ℃)的装载区 | |
日本 | 罗森 | CO2制冷系统 | 20%的节能,一半归功于CO2系统,另一半归功于新型CO2展柜(即滑动玻璃门)的节能功能 | |
北美洲 | 美国,加利福尼亚州 | 约塞米蒂食品公司 | 世界上最大的CO2制冷系统 | 该设施于2019年在加州安装。5个制冷设备为18 580 m2的设施提供冷量 |
美国,明尼阿波利斯 | Lunds & Byerlys store | 跨临界CO2增压制冷系统 | 在Lunds & Byerlys的一个处理设备上安装了1个跨临界CO2增压制冷系统 | |
美国,那不勒斯 | — | 跨临界CO2增压制冷系统 | 该系统包括3个屋顶绝热气体冷却器,有助于该系统在佛罗里达州西南部温暖的气候中有效运行。经大致评估得出其能耗与传统系统相比一致或高些许 | |
美国 | 阿尔迪 | 跨临界CO2增压制冷系统 | 2017年8月11日,阿尔迪的69家门店采用了跨临界CO2增压制冷系统 | |
加拿大 | 零售商巨头Sobeys | 跨临界CO2增压制冷系统 | 2015年时拥有1 778家商店,其中78家已经使用了跨临界CO2增压制冷系统,且每年新开设的15~20家商店也将使用CO2作为制冷剂 | |
南美洲 | 哥伦比亚,卡利 | Valle del Lili | 跨临界CO2增压制冷系统 | 该系统与平行压缩相结合,使中温侧制冷量达到130 kW,低温侧制冷量达到4 kW。该装置还包括1个气体冷却器、电子膨胀阀和自动门,所有这些都是为最大限度地提高能源效率,减少商店的碳足迹 |
非洲 | 南非,约翰内斯堡 | Food Lovers Market | CO2增压制冷系统 | 安装了1套CO2增压制冷系统,中温侧制冷量为177 kW,低温侧制冷量为58 kW |
南非,开普敦 | Pick n Pay(PnP) | 平行压缩CO2增压制冷系统 | 在当地制造的制冷系统上装有10台压缩机,其中4台为高压级压缩机,2台为平行压缩机,3台为低压机压缩机,1台卫星压缩机。系统中包含1个板式热交换器,用于回收热量 | |
大洋洲 | 澳大利亚,墨尔本 | 沃尔沃斯伯伍德 | 跨临界CO2增压制冷系统 | 使用了3个跨临界CO2增压制冷系统,2个用于超市的冷却器和冰柜,1个用于位于购物中心内的丹·墨菲酒店。2个系统都包括并行压缩机。此外,所有肉类和奶制品箱都装有门,防止冷空气从箱中溢出,使能源消耗减少约30% |
澳大利亚,克莱斯韦克 | IGA Supa | CO2制冷系统 | 采用CO2制冷系统使碳足迹减少47%,年排放量减少6 209 t。此外该系统具有储热功能,可利用CO2制冷系统产生的余热生产热水,进一步降低成本和排放 | |
新西兰 | Fresh Choice Papamoa和Countdown 食品零售店 | 跨临界CO2增压制冷系统 | 2019年开业,均采用节能跨临界CO2增压制冷系统。据估计2家商店比新的设计良好的等效HFC系统在能源使用方面节省5%~8% |
Tab.4
Typical operating parameters of four supermarkets taking CO2 refrigeration systems[17]
商超 | 系统 | 低温制冷量/kW | 中温制冷量/kW | 总功率/kW | 商超运营信息 |
---|---|---|---|---|---|
中国麦德龙北京立水桥商场 | 跨临界CO2增压制冷系统 | 74.08 | 370.42 | 333.55 | 2018年1月17日开业 |
北京超市发玉泉路店 | 跨临界CO2增压制冷系统 | 21.90 | 54.34 | 45.59 | 2018年4月升级改造,10月开店,CO2制冷超市应用示范项目之一 |
安徽商之都红府超市合肥中心广场店 | R134a/CO2 复叠制冷系统 | 13.89 | 68.85 | 37.10 | 2017年9月正式营业,CO2制冷超市应用示范项目之一 |
华联超市武汉群星城店 | R134a/CO2 复叠制冷系统 | 35.18 | 118.29 | 57.69 | 2017年3月开业 |
[1] | 滑雪, 王文华, 刘圣春, 等. 超市绿色制冷剂应用现状与实践[J]. 制冷与空调, 2019, 19(9):59-70. |
HUA Xue, WANG Wenhua, LIU Shengchun, et al. Application status and practice of green refrigerant in supermarkets[J]. Refrigeration and Air-conditioning, 2019, 19(9):59-70. | |
[2] |
TASSOU S A, GE Y, HADAWEY A, et al. Energy consumption and conservation in food retailing[J]. Applied Thermal Engineering, 2011, 31:147-156.
doi: 10.1016/j.applthermaleng.2010.08.023 |
[3] |
GULLO P, HAFNER A, BANASIAK K. Transcritical R744 refrigeration systems for supermarket applications:Current status and future perspectives[J]. International Journal of Refrigeration, 2018, 93:269-310.
doi: 10.1016/j.ijrefrig.2018.07.001 |
[4] | 中国连锁经营协会. 超市制冷设备HCFC制冷剂使用现状研究报告[R]. 2019. |
[5] | CALM J M, HOURAHAN G C. Physical,safety,and environmental data for current and alternative refrigerants [C].23rd International Congress of Refrigeration,Prague,Czech Republic, 2011. |
[6] | 中华人民共和国生态环境部. 我国正式接受《〈关于消耗臭氧层物质的蒙特利尔议定书〉基加利修正案》[EB/OL].(2021-06-21)[2021-08-25]. http://www.mee.gov.cn/xxgk/hjyw/202106/t20210621_841062.shtml. |
[7] |
GULLO P, HAFNER A, CORTELLA G. Multi-ejector R744 booster refrigerating plant and air conditioning system integration—A theoretical evaluation of energy benefits for supermarket applications[J]. International Journal of Refrigeration, 2017, 75:164-176.
doi: 10.1016/j.ijrefrig.2016.12.009 |
[8] | SHECCO. World guide to transicritical CO2 refrigeration[R]. 2020. |
[9] |
TSAMOS K M, GE Y T, TASSOU S A, et al. Energy analysis of alternative CO2 refrigeration system configurations for retail food applications in moderate and warm climates[J]. Energy Conversion and Management, 2017, 150:822-829.
doi: 10.1016/j.enconman.2017.03.020 |
[10] | MATTHIESEN O, MADSEN K, MIKHAILOV A. Evolution of CO2 systems design based on practical experiences from supermarket installations in Northern Europe [C].Proceedings of the 9th IIR Gustav Lorentzen conference on natural working fluids,Sydney,Australia, 2010. |
[11] | ANDRE P, ANTONIO D L. Natural refrigerant alternatives for industrial refrigeration[R]. Emerson.E360 Forum, 2017. |
[12] | 钟志峰, 李小燕, 王文华, 等. 超市用跨临界CO2制冷技术考察调研报告[R]. 2016. |
[13] |
GULLO P, ELMEGAARDl B, CORTELLA G. Energy and environmental performance assessment of R744 booster supermarket refrigeration systems operating in warm climates[J]. International Journal of Refrigeration, 2016, 64:61-79.
doi: 10.1016/j.ijrefrig.2015.12.016 |
[14] | 曹锋, 叶祖樑. 商超跨临界CO2增压制冷系统及技术应用现状[J]. 制冷与空调, 2017, 19(9):68-75. |
CAO Feng, YE Zuliang. Current situation of quotient transcritical CO2 booster refrigeration system and its application[J]. Refrigeration and Air-conditioning, 2017, 19(9):68-75. | |
[15] |
DILSHAD S, KALAIR A, KHAN N. Review of carbon dioxide(CO2) based heating and cooling technologies:Past,present,and future outlook[J]. International Journal of Energy Research, 2020, 44(3).DOI: 10.1002/er.5024.
doi: 10.1002/er.5024 |
[16] |
ZOLCER SKACANOVA K, BATTESTI M. Global market and policy trends for CO2 in refrigeration[J]. International Journal of Refrigeration, 2019, 107:98-104.
doi: 10.1016/j.ijrefrig.2019.08.010 |
[17] | YOSHIMOTO D, DUSEK J, 陶赢玮. 蓝天思维:中国零售业首个跨临界二氧化碳系统[EB/OL]. Accelerate 中国, 2018:22-31.[2021-10-11]. http://publication.shecco.com/publications/view/221. |
[18] | GARRY M. 跨临界二氧化碳制冷系统机组领跑者[EB/OL]. Accelerate中国, 2018:42-45.[2021-10-11]. http://publication.shecco.com/publications/view/221. |
[19] | 马一太, 李敏霞, 田华, 等. CO2循环在商业制冷领域的应用[J]. 制冷与空调, 2017, 17(9):91-93. |
MA Yitai, LI Minxia, TIAN Hua, et al. Application of CO2 cycle in commercial refrigeration field[J]. Refrigeration and Air-conditioning, 2017, 17(9):91-93. | |
[20] |
PAPASAVVA S, MOOMAW W. Life-cycle global warming impact of CFCs and CFC-substitutes for refrigeration[J]. Journal of Industrial Ecology, 2008, 1(4):71-91.
doi: 10.1162/jiec.1997.1.4.71 |
[21] | International institute of refrigeration,life cycle climate performance working group. Guideline for life cycle climate performance[R/OL].2016. http://www.cold.org.gr/library/downloads/Docs/Guideline%20for%20life%20cycle%20climate%20performance.pdf. |
[22] | SKAČANOVÁ K Z. 从小众到主流——天然制冷剂之路[EB/OL]. Accelerate中国, 2019:12-17.[2021-10-11]. http://publication.shecco.com/publications/view/223. |
[23] | BATTESTI M. 政策发力,促进天然制冷剂使用[EB/OL]. Accelerate中国, 2019:18-21.[2021-10-11]. http://publication.shecco.com/publications/view/223. |
[24] | 胡健. 一种跨临界CO2热泵系统的设计[J]. 华电技术, 2020, 42(12):67-71. |
HU Jian. Design of a transcritical CO2 heat pump system[J]. Huadian Technology, 2020, 42(12):67-71. | |
[25] | 顾志祥, 刘洁, 孔飞, 等. 楼宇型分布式能源站空调水平衡影响分析[J]. 华电技术, 2019, 41(4):47-50. |
GU Zhixiang, LIU Jie, KONG Fei, et al. Analysis on influence of air conditioning water balance in building-type distributed energy station[J]. Huadian Technology, 2019, 41(4):47-50. |
[1] | JIANG Ting, ZHAO Yajiao. Carbon emission reduction analysis for gas-based distributed integrated energy systems [J]. Integrated Intelligent Energy, 2022, 44(9): 27-32. |
[2] | WANG Kaiting, LI Xiaobin, ZHANG Hongna, LIU Shen, QU Kaiyang, LI Fengchen. Comprehensive evaluation for energy saving and emission reduction performance of turbulent drag reducing agent in heating systems [J]. Integrated Intelligent Energy, 2022, 44(9): 40-50. |
[3] | ZHANG Rongquan, LI Gangqiang, BU Siqi, LIU Fang, ZHU Yuxiang. Economic operation of a multi-energy system based on adaptive learning rate firefly algorithm [J]. Integrated Intelligent Energy, 2022, 44(7): 49-57. |
[4] | XIE Dian, GAO Yajing, LU Xinbo, LIU Tianyang, ZHAO Liang, ZHAO Yong. Research on the implementation path of the transition from dual control on energy consumption to dual control on carbon emission [J]. Integrated Intelligent Energy, 2022, 44(7): 73-80. |
[5] | Yating GUO, Tianyin DENG, Yanying LIU, Guangli HE. Research on the performance of membranes and anode materials in alkaline water electrolysis [J]. Integrated Intelligent Energy, 2022, 44(5): 64-68. |
[6] | Hengyuan GUO, Xiaofeng FENG, Guodong LI, Zhiguo DUAN, Yuanzheng LI. Low-carbon collaborative optimization for the commitment and maintenance of units considering hydrogen production equipment [J]. Integrated Intelligent Energy, 2022, 44(5): 78-87. |
[7] | WANG Sheng, TAN Jian, MA Yahui, ZOU Fenghua. Impact factor analysis and forecasting of the carbon emissions from industries based on LMDI method under multiple uncertainties: The case of Suzhou City [J]. Integrated Intelligent Energy, 2022, 44(2): 1-7. |
[8] | WANG Yizheng, HU Jiahua, TANG Qiwen, ZHAO Yiyan, SHEN Qi. Hydropower generation optimization and photovoltaic generation consumption in the spot market for electricity [J]. Integrated Intelligent Energy, 2022, 44(2): 73-79. |
[9] | XU Hengzhi, ZHOU Bowen, LI Guangdi, HUA Guanghui, KONG Xiangmiao. Research on optimal operation of the regional integrated energy system with water-source heat pumps [J]. Integrated Intelligent Energy, 2022, 44(1): 39-48. |
[10] | LAN Jing, ZHU Jizhong, LI Shenglin, SHI Puxin, GUO Wanshu, SHI Peiran, JIANG Changming. Research on electrochemical energy storage to assist new energy consumption and peak load regulation considering carbon penalty [J]. Integrated Intelligent Energy, 2022, 44(1): 9-17. |
[11] | ZHANG Jiarui, YU Pengjun, XU Zhongyi, XU Jiabao, ZHU Zewei. Environmental economic dispatch considering wind power systems based on green certificate-carbon trading mechanism [J]. Huadian Technology, 2021, 43(9): 69-77. |
[12] | YU Xiaobao, ZHENG Dandan, YANG Kang, KONG Jie, ZHANG Tianhao. Opportunities and challenges faced by energy and power industry with the goal of carbon neutrality and carbon peak [J]. Huadian Technology, 2021, 43(6): 21-32. |
[13] | JI Bin, SUN Hui, LIANG Xiao, LIU Yan, LI Fan. Discussion on convergent trading of the carbon and electricity market on the path to carbon peak and carbon neutrality [J]. Huadian Technology, 2021, 43(6): 33-40. |
[14] | WU Tong, ZHANG Xingyu, CHENG Xingxing, SUN Rongfeng, WANG Zhiqiang, GENG Wenguang, WANG Luyuan, FENG Tai. Analysis and prediction of industrial carbon emission of Linyi City based on STIRPAT model [J]. Huadian Technology, 2021, 43(6): 47-54. |
[15] | YIN Shuo, GUO Xingwu, YAN Jing, YANG Qinchen, ZHANG Peng. Study on optimized operation on integrated energy system in parks with high permeability and carbon emission constraints [J]. Huadian Technology, 2021, 43(4): 1-7. |
Viewed | ||||||
Full text |
|
|||||
Abstract |
|
|||||