Huadian Technology ›› 2008, Vol. 30 ›› Issue (8): 13-15.

• 专题综述 • Previous Articles     Next Articles

The Peak-shaving Operation Analysis of S109FA Gas-Steam Combined Cycle Unit

MAO Hua-jun   

  1. Wangting Power Plant, Suzhou 215155, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2008-08-25 Published:2008-08-25

Abstract: The peak-shaving gas turbine usually starts up at morning and shuts down at evening, the influence of this operation mode on the unit maintenance interval, the equipment safety and economic operation, the unit efficiency and the environment protection was analyzed in detail. And it is put forward finally that the peak-shaving operation and frequent starting and shutting would be avoided in the selection of gas turbine set operation mode if possible.

Key words: gas turbine, peak-shaving operation, frequent start-up, reliability, safety, efficiency, environment protection