Huadian Technology ›› 2016, Vol. 38 ›› Issue (6): 63-70.

Previous Articles     Next Articles

600MW sub critical unit boiler SCR improvement test research

  

  1. Zhanjiang Zhongyue Energy Company Limited, Zhanjiang 524000, China
  • Online:2016-06-25 Published:2016-09-21

Abstract:

Abstract:Based on the condition of a subcritical 600MW selective catalytic reduction (SCR) abnormal large ammonia consumption, denitration system operation difficult, NOx large fluctuation and air preheater blockage and other problems, the author analyzed the outlet  NOxdensity and flow field. By adjusting ammonia injection grid, the unit operation was optimized, density field was almost equally distributed. Testing point deviation was lowered to under 15%. Decreasing of air preheater resistance pressure difference reach to 26.13%.

Key words: