Huadian Technology ›› 2012, Vol. 34 ›› Issue (5): 67-70.

• 节能与环保 • Previous Articles     Next Articles

Optimization of boiler fed by doubleended ball mill for energy conservation

LIU Yanpeng1, MA Bin1, DONG Yufang2   

  1. 1.Anhui Electric Power Research Institute, Hefei 230601, China; 2.State Nuclear Power Engineering Company Limited, Shanghai 317112, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-05-25 Published:2012-05-25

Abstract:

The fundamental principle of optimization operation of boiler for energy conservation was given. Taking the boiler fed by doubleended ball mill

directfiring system as example, the optimization operation technology of the boiler under 70% rated load for energy conservation was studied and tested.

The result shows that when the boiler is under rated load, it is necessary to stop one of the three mills and to pay attention to the influence of the

combining operation mode of the operating mills on the energy consumption of the unit.

Key words: boiler, direct-firing pulverizing system, double-ended ball mill, energy conservation