Huadian Technology ›› 2009, Vol. 31 ›› Issue (11): 45-46.

• 技术交流 • Previous Articles     Next Articles

Treatment measures for frequently startup and stop of oil pump in hydraulic turbine governor

CHEN Wei   

  1. Huadian Fujian Shaxian Chengguan Hydroelectric Corporation Limited, Shaxian 365500, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2009-11-25 Published:2009-11-25

Abstract: In a hydropower station of Huadian Fujian Shaxian Chengguan Hydroelectric Corporation Limited, the governor oil pump startedup and shut down frequently while the governor was outage state or worked without adjusted load, and this may be caused by fault existed in the governor system. This problem was analyzed, some effects were adopted, and the fault was eliminated basically.