Huadian Technology ›› 2010, Vol. 32 ›› Issue (9): 30-32.

• 研究与开发 • Previous Articles     Next Articles

Analysis of Influence of slag disposal system reformation on boiler outlet gas temperature

LIU San, LIU Bing   

  1. Huadian International Zouxian Power Plant, Zoucheng 273522, China
  • Received:1900-01-01 Revised:1900-01-01 Published:2010-09-25

Abstract: The wet slag disposal system of boiler number 6 in Zouxian Power Plant had been reformed to be dry slag disposal system. After this reformation, the temperature of boiler outlet gas was increased. By comparing the relevant parameters before and after reformation with each other, the reason of outlet gas temperature increase was found, and concrete solving scheme and countermeasures were put forward.

Key words: dry slag disposal, outlet gas temperature, efficiency