Huadian Technology ›› 2012, Vol. 34 ›› Issue (2): 7-10.

• 专题综述 • Previous Articles     Next Articles

Application of oxygen soft measurement system in 600MW supercritical boiler

ZHOU Liqun1,ZHANG Bifang2,XU Zhongchuan1   

  1. 1.Fujian Huadian Kemen Power Generation Company Limited, Fuzhou 350512, China; 2.Fujian Huadian Zhangping Thermal Power Company Limited, Zhangping 364400, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-02-25 Published:2012-02-25

Abstract:

The problems existing in traditional oxygen metering and the advantages of the soft oxygen measuring system were analyzed. The soft oxygen

measurement system had been used in a 600MW supercritical boiler; the oxygen control was optimized; the power consumption of air and flue gas system was

reduced; the boiler operation safety was ensured, and the boiler operation efficiency was enhanced. 