Huadian Technology ›› 2012, Vol. 34 ›› Issue (S1): 33-35.

• 技术交流 • Previous Articles     Next Articles

Analysis on optimization of quick start of 9E combined cycle generating unit

ZHAO Han   

  1. Shanghai Fengxian Gas Turbine Power Generation Company Limited, Shanghai 201403, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2012-11-10 Published:2012-11-10

Abstract: Taking the 9E gassteam combined cycle power generating unit of Shanghai Fengxian Gas Turbine Power Generation Company Limited as example, the optimization method on quick start of the unit was introduced. The energysaving effect of the optimized unit was analyzed. The result in this paper provides reference for handling with similar problems.

Key words: gas turbine, steam turbine, gas-steam combined cycle power generation, quick start, optimization