Analysis of the operation characteristics of 330MW set′s SCR denitrification system SUI Xiukun

  

  1. (Guodian Jilin Jiangnan Thermal Power Company Limited, Jilin 132011, China
  • Online:2015-06-25 Published:2015-10-08

Abstract:

Abstract:With 330MW set in Jilin Jiangnan Thermal Power Company Limited as object case, the researcher studied the effect of selective catalytic reduction (SCR) based FGD deviceon boiler; then conducted check calculation on the boiler′s basic parameters, coal quality parameters and SCR de NO  x  system operation data, and the operation optimization measures of SCR de NOx system were proposed.

Key words: Keywords:boiler, selective catalytic reduction, denitrification, environmental protection, optimization