Huadian Technology ›› 2019, Vol. 41 ›› Issue (1): 45-49.

Previous Articles     Next Articles

Optimization of operational and cleaning method of predesalination system in thermal power plants

  

  1. Yunnan Huadian Kunming Power Generation Company Limited, Kunming 650308, China
  • Online:2019-01-25 Published:2019-02-14

Abstract:

To solve the problem of low water production rate in predesalination system of a power generation company, measures for equipment maintenance, system operation mode adjustment and cleaning mode adjustment are proposed after analyzing the water quality and equipment operation mode. The methods effectively improve the water production rate in predesalination system and its cleaning effect. The silting density index in reverse osmosis system is reduced. The safety and economy of the predesalination system is enhanced.

Key words: